AirCare Automation provides a full set of peripheral and accessory items to allow you to incorporate our products into your system seamlessly. We provide cables, housing and specialty function parts to allow you to test and install your desired system solution.
| 1. Power Sources
|
|
|
|
|
|
Bus Power Supply - ACM1005 |
Wall mounted power converter for GE-ECM system powering. Will power 10-12 ACM1004 boards (40-48 motors) over the CAT5 communication cables along with and ACC1-xx and one ACM1007 board The unit is wall mounted and connects to the AC power through a standard outlet plug.
>> Download ACM1005 Datasheet [PDF: 193kb]
Please contact us for more information.
|
|
|
|
|
|
|
Network Power Supply - ACM1008 |
Board level power supply that provides DC power to the CAT5 cables for GE-ECM system powering. Will power 10-12 ACM1004 boards (40-48 motors) over the CAT5 communication cables along with and ACC1-xx and one ACM1007 board . The unit is open board, needing to be placed in an enclosure and connects to the AC power through an AC transformer (supplied) to hard wire to an AC power source.
>> Download ACM1008 Datasheet [PDF: 193kb]
Please contact us for more information.
|
|
|
|
| 2. Specialty Modules
|
|
|
|
|
|
Remote Hi/Lo Board Module- ACM1007
|
This board will allow an intelligent controller or manual switch to be used to
control the Hi/Lo status of the ACC1 or ACC2 Consoles. Once the board is inserted
in the network (one per zone) the board then overrides the knob controls and sets
the Hi/Lo status.
Potential uses are:
- Use a manual switch to set Hi/Lo so the user does not have to operate the Console
(it can be closed off)
- Have a PCor other Building Management System (BMS) communicate with the AirCare
Console and control the set Hi/Lo times through its programming (i.e. clock/calendar
of the PC or BMS )
>> Download ACM1007
Datasheet [PDF: 204kb]
Please contact us for more information.
|
|
|
|
| 3. Cables and Connectors
|
|
|
|
|
|
Basic speed potentiometer |
Speed potentiometers come with the matching terminal block for the ACVxxxx family of products to control the units manually or help pre-set the speed through the analog port.
A free standing pot that will mount into the users housing is the standard model and an enclosed unit is provided as a premium selection.
Please contact us for more information.
|
|
|
|
|
ECM Motor Interface Cable |
Cables for MODBUS Interface (ACM1002/1004) utilization for GE ECM Motors
Please contact us for more information.
|
|
|
|
|
Patch Cable |
Cables to hook up the units for network communication. We provide cables of 3ft, 10ft, 25ft, 50ft, 75ft and 100ft.
Please contact us for more information.
|
|
| 5. Air Flow Sensor - ACM1006
|
|
|
|
|
|
ACM1006 Air Flow Sensor enables low cost, closed-loop control of your fan system using AirCare VariPhaseTM and AirCare Interface Modules.
>> Download ACM1006 Datasheet [PDF: 81kb]
- Set point and range specified with part number (set point +/- 50% is the recommended range)
- Typical 1% change in set point = 1-2% change in set-point air-flow
- Simple connections: screw terminals for output
- Open-frame PCB with mounting bracket or optional rugged enclosure
- 0-50 C operating temperature
- 5.5" x .5" x .06" (board only)
|
|
|
|
| 6. Invertek Drives Interface Module - ACM1001
|
|
|
|
|
|
ACM1001 Interface Module provides MODBUS communication interface to both Invertek OptiDrive or E-Drive products and interfaces seamlessly into the AirCare Small System platform.
>> Download ACM1001 Datasheet [PDF: 351kb]
- Modbus RTU network interface
- Work with any Invertek OptiDrives and new E-Drive platforms
- Closed loop control option
- Integrated Power Meter Function
- Diagnostic LED for network status
- Powered from drive - no external supply required
|
|
|
|
| 7. VariPhaseTM Development Tools
|
|
|
|
|
|
AirCare VariPhaseTM Eval Kit |
Built with MODSCAN software, this PC-interfaced evaluation kit offers easy-to-use template
and includes all cables. Part # ACVEVAL00x (1,2,3).
- 1 - MODSCAN 90 day demo
- 2 - ACV10xx – 3 or 4 A VariPhase of your Voltage choice
- 1 - RS232/485 converter Cables and connectors
Please contact us for more information.
|
|
|
|
| 8. Cleanroom Demo Systems
|
|
|
|
|
|
AirCare Automation makes it simple to evaluate and demonstrate our Small Cleanroom solutions. We provide a low-cost, easy to use demonstration system to evaluate and demonstrate the VariPhase, GE-ECM and Console system products and accessories:
Each Demo System has a 10 address console (ACC1-10) a remote set-back module (ACM1007) and a group of selected VariPhase or Interface boards along with associated CAT5 patch cables. The VariPhase (ACV104x) or ECM interface cards (ACM1004) are configured for the small system control. Therefore will work “out-of-the-box”.
Each Demo system includes: ACC1-10, 1- 10’ CAT5 patch cable, 3’ patch cables for each additional ACV or ACM card. All card are configured and addressed for operation.
- AC Demo Systems
ACVDEMO001 Demo system - for Single phase AC fan 115 volt (4 ampere rated) 4 ACV1041 provided
ACVDEMO002 Demo system - for Single phase AC fan 230 volt (4 ampere rated) 4 ACV1042 provided
ACVDEMO003 Demo system - for Single phase AC fan 277 volt (3 ampere rated) 4 ACV1033 provided
- DC Demo System
ACMDEMO001 Demo system – for GE-ECM motors (specify 115 or 230 volt connections) - 2 ACM1004 + 4 motor cables (2-cable) for ECM interface
- AC/DC Combination Demo System – for both AC and DC samples for evaluation and demonstration of both baseline technologies:
ACVDEMOAD1 – 2 ACV1041 (115V) and one ACM1004 (4- motor ECM motor) with 2 sets of ECM motor cables
ACVDEMOAD2 – 2 ACV1042 (230V) and one ACM1004 (4- motor ECM motor) with 2 sets of ECM motor cables
ACVDEMOAD3 – 2 ACV1033 (277V) and one ACM1004 (4- motor ECM motor) with 2 sets of ECM motor cables
Contact us for more information.
|
|
|
|
|
|